Column Selection Showcases

I collected some column selection showcases from column manufacturers.

Agilent Column Selection Guide #

Figure : Choose Column Configuration for Application
Figure : Resolving Power
Figure : Pick the Column and Particle Size to Meet Your Needs
Figure : Smaller Particles Maintain Efficiency Over Wider Flow Rate Ranges
Figure : Different C18 Bonded Phases for Max Selectivity
Figure : Analytical - 4.6x250mm, 5.0µm PAH Column – Separation of 16 PAH’s in EPA 610
Figure : Rapid Resolution – 4.6x150mm, 3.5µm PAH Column – Separation of 16 PAHs in EPA 610
Figure : - Rapid Resolution Eclipse - 4.6x50mm, 3.5µm PAH Column – Separation of 16 PAHs in EPA 610
Figure : Rapid Resolution HT Eclipse - 4.6x100mm, 1.8µm PAH Column - Separation of 16 PAHs in EPA 610
Figure : Rapid Resolution HT Eclipse - 4.6x50mm, 1.8µm PAH Column – Separation of 16 PAHs in EPA 610
Figure : Solvent Saver Eclipse - 3.0x250 mm, 5µm PAH Column - Separation of 16 PAHs in EPA 610
Figure : Narrow Bore Eclipse - 2.1x250 mm, 5µm PAH Column - Separation of 16 PAHs in EPA 610
Figure : Narrow Bore Rapid Resolution Eclipse - 2.1x100mm, 3.5µm PAH Column - Separation of 16 PAHs in EPA 610
Figure : Narrow Bore RRHT Eclipse - 2.1x100mm 1.8µm PAH Column – Separation of 16 PAHs in EPA 610
Figure : Narrow Bore RRHT Eclipse - 2.1x50mm, 1.8µm PAH Column - Separation of 16 PAHs in EPA 610
General Phase Type Starting ZORBAX Choice
Typical “endcapped” C18 or C8
bonded phases, newer columns Eclipse Plus C18 or C8
Endcapped C18 or C8 columns,
older generation Eclipse XDB-C18 or C8
Non-endcapped columns StableBond C18
Older types of columns StableBond C18, C8 etc.
Aqueous “type” columns SB-AQ
CN or Phenyl SB-CN, SB-Phenyl

source

Thermo Column Selection Guide #

Thermo Scientific reversed phase materials are based on high purity silicas giving excellent chromatography of acids, bases, and neutral compounds. Our premier columns include Hypersil GOLD and BioBasic families in a wide range of chemistries, an excellent choice for all of your chromatography needs. Choose any of our families for method development, LC/MS, and your most demanding separations. All of our reversed phase materials offer superb reproducibility and reliable performance for routine and QC analyses. Our experienced Technical Support staff are always able to help you select the appropriate column for your application.

Premium Columns #

Hypersil GOLD™ Columns: The key to outstanding peak shape
• Exceptional peak symmetry and resolution
• Based on next-generation ultra pure silica
• Outstanding pH stability
• Ideal first choice for new method development

BioBasic™ Columns: Better chromatography of biomolecules
• 300Å pore size for better protein and peptide separations
• Excellent reproducibility, efficiency, and column lifetimes
• Range of stationary phases to optimize selectivity, including ion exchange and size exclusion
• Ideal for proteomics and LC/MS of biomolecules
• Excellent alternative to Vydac®, YMC-Pack™ and Zorbax® wide pore columns

Classical Hypersil™ Columns #

Thermo Scientific Classical Hypersil reversed phase chemistries provide a proven record of performance for routine analyses year after year. Specified in thousands of methods worldwide, our classical Hypersil families offer exceptional reproducibility and reliability.

Hypersil BDS Columns: The standard base deactivated column
• Base deactivated for reduced peak tailing and excellent peak symmetry
• Highly reproducible and efficient
• Reliable with long column lifetimes
• Excellent performance with basic, acidic and neutral compounds

Hypersil Classical Columns: Reliable and reproducible
• Excellent phase used for thousands of existing methods
• High efficiency, proven reproducibility, and long column lifetimes
• Wide range of bonded phases including dedicated columns for specific applications

Performance Columns #

HyPURITY™ Columns: The choice for superior chromatography
• Ultra-pure, highly stable silica for long column lifetime, reliability and performance
• Excellent peak shapes for acids, bases, chelators and neutral compounds
• 190Å pore size for small molecules, peptides, and protein digests
• Family of phases for a variety of selectivities
• Ideal for LC/MS applications
• Excellent alternative to other highly pure silica columns

BetaBasic™ Columns: Stable, inert and reproducible for general HPLC
• Superb stability at both high and low pH
• Efficient and reproducible columns
• A family of useful stationary phases
• 150Å pore size for small molecules, peptides and protein digests

BETASIL™ Columns: High retention, efficiency and selectivity
• Highly retentive phases with excellent peak shapes and lifetimes
• High surface area with high bonded phase coverage
• Phases with unique selectivity for reversed phase and normal phase
• Ideal for LC/MS applications, including short, fast DASH™ columns
• Excellent substitute for Inertsil® columns

BetaMax™ Columns: Maximum retention for maximum results
• Ultra-high surface area and surface coverage for maximum retention
• 3 chemistries for 3 types of analytes: acid, base, and neutral
• Excellent stability for long column lifetimes
• BetaMax Neutral provides maximum C18 reversed phase retention for LC/MS applications

Unique Selectivities #

Hypercarb™ Columns: 100% porous graphitic carbon solves problematic separations
• Exceptional retention of polar compounds
• pH stable from 1 to 14
• Separate structurally similar compounds
• Ideal for LC/MS applications other non-silica based columns

Hypersil GOLD aQ Columns: Retention of polar compounds • Polar end-capped reversed phase columns for enhanced retention of polar compounds • Compatible with 100% aqueous mobile phases and standard reversed phase mobile phases • Run with reduced buffer concentrations • C18 phase for reliability and high performance.

Hypersil GOLD PFP Columns: Fluorinated phases for highly selective reversed phase chromatography • Fluorinated phase provides unique selectivity • Extra retention and selectivity for fluorinated and chlorinated compounds • Excellent selectivity for polar nonhalogenated compounds with nitro, hydroxyl, carboxyl and other polar groups • Shape selective for structural isomers • Use typical reversed phase solvents and conditions

Hypersil GOLD Phenyl Columns: Alternative selectivity for aromatic and moderately polar analytes • Butyl linker provides enhanced pi-pi interactions with aromatics • Moderate hydrophobicity • Outstanding peak shape and sensitivity

HyPURITY ADVANCE™ Columns: Polar embedded phase for reversed phase chromatography • Unique reversed phase selectivity • Ideal for the separation of polar compounds

Thermo’s guide

Shodex Column Selection Guide #

Shodex’s guide